Model |
OM-148 |
Type |
Combustion Type – Pressure Vapor
Flue Pipe – Forced Flue
Heating – Instantaneous
Source of Water – Direct Connection to Main Supply |
Ignition |
High Voltage Discharge Spark |
Fuel Type: |
ASTM D3699 K1 KEROSENE
ASTM D396 NO.1 LOW SULFUR FUEL OIL
ASTM D975 ULTRA LOW SULFUR HEATING OIL/ DIESEL
ASTM D396 No.2 FUEL OIL (HOME HEATING OIL) |
Efficiency |
87%(1) |
Hot Water Output |
148,000 BTU/h |
Fuel Consumption |
1.1 gal./h |
Max. Hot Water Temperature |
155°F (approximately) |
Water Flow Rate/
Temperature Rise: |
6.1 gal./min. (40°F rise)
4.8 gal./min. (50°F rise)
4.0 gal./min. (60°F rise)
3.5 gal./min. (70°F rise)
3.0 gal./min. (80°F rise) |
Capacity of Heat Exchanger |
5.10 gal. |
Area of Heat Transmission |
9.7 ft.2 |
Fuel System |
Tank(1) |
Dimensions (W x H x D) |
12-5/8″ x 27-3/4″ x 22-1/2″ |
Weight |
81 lbs. Empty |
Vent Pipe Hole |
4-3/4″ diameter |
Max. Length of Vent Pipe |
10 ft., 3 bends or les |
Electric Rating |
120 Volts AC, 60 Hz
Ignition – 110W
Burning – 98W |
Required Accessories |
Fuel Strainer, Temp. & Pressure Relief Valve |
Exhaust Air Temperature |
Less than 500°F |
Nozzle |
Quantity of Vapor – 0.85 GPH Delavan type XA
Spraying Angle – 60° |
Temperature Fuse |
282°
|
Electric Current Fuse |
5A |
(1) Existing tank or purchase tank from local supplier.